Digi-Frame DF-1044r Bedienungsanleitung Seite 460

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 829
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 459
Remote Control
R&S
®
RTO
444User Manual 1316.0827.02 ─ 06
Parameters:
<ProbeGainModeManual>Range: 100E-6 to 10
Increment: 0.01
*RST: 0.1
Default unit: V/V
PROBe<m>:SETup:MEASurement <ProbeMeterMeas>
Selects the input voltage that is measured by the differential active probe.
See also: "Differential active probes" on page 22.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ProbeMeterMeas> DIFFerential | COMMonmode
DIFFerential
Measures the voltage between the positive and negative signal
sockets.
COMMonmode
Measures the mean voltage between the signal sockets and the
ground socket.
*RST: NONE
CHANnel<m>:EATScale <ExtAttScale>
Sets the attenuation scale for an external divider.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ExtAttScale> LIN | LOG
*RST: LIN
CHANnel<m>:EATTenuation <ExtAtt>
Sets the attenuation of an external voltage divider.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ExtAtt> Range: 1E-3 to 1000
Increment: 0.01
*RST: 1
Default unit: The unit depends on the selected scale.
Command Reference