Digi-Frame DF-1044r Bedienungsanleitung Seite 536

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 829
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 535
Remote Control
R&S
®
RTO
520User Manual 1316.0827.02 ─ 06
Parameters:
<EnvelopeCurve2> MIN | MAX | BOTH
MIN
The horizontal cursor is set to the crossing point of the vertical
cursor with the minimum waveform envelope.
MAX
The horizontal cursor is set to the crossing point of the vertical
cursor with the maximum waveform envelope.
BOTH
The envelope is ignored and the cursor is set to the crossing point
of the vertical cursor with the usual waveform
*RST: MIN
CURSor<m>:XDELta[:VALue]?
Queries the delta value (distance) of two vertical cursor lines.
Suffix:
<m>
.
1..4
Selects the cursor.
Return values:
<Delta> Range: -100E+24 to 100E+24
Increment: 0.1
*RST: 0
Default unit: s
Usage: Query only
CURSor<m>:XDELta:INVerse?
Queries the inverse value of the delta value (distance) of the two vertical cursor lines.
Suffix:
<m>
.
1..4
Selects the cursor.
Return values:
<DeltaInverse> Range: -100E+24 to 100E+24
Increment: 0.1
*RST: 0
Default unit: Hz
Usage: Query only
CURSor<m>:YDELta[:VALue]?
Queries the delta value (distance) of the two horizontal cursor lines.